Skip to main content

Lift Control API

API that configures the OM-120, which can control lifts.



Structure​

BS2Lift​

typedef struct {
BS2_LIFT_ID liftID;
char name[BS2_MAX_LIFT_NAME_LEN];

BS2_DEVICE_ID deviceID[BS2_MAX_DEVICES_ON_LIFT];

uint32_t activateTimeout;
uint32_t dualAuthTimeout;

uint8_t numFloors;
uint8_t numDualAuthApprovalGroups;
BS2_DUAL_AUTH_APPROVAL dualAuthApprovalType;
BS2_BOOL tamperOn;

BS2_BOOL dualAuthRequired[BS2_MAX_DEVICES_ON_LIFT];
BS2_SCHEDULE_ID dualAuthScheduleID;

BS2LiftFloor floor[BS2_MAX_FLOORS_ON_LIFT];
BS2_ACCESS_GROUP_ID dualAuthApprovalGroupID[BS2_MAX_DUAL_AUTH_APPROVAL_GROUP_ON_LIFT];

BS2LiftAlarm alarm[BS2_MAX_ALARMS_ON_LIFT];
BS2LiftAlarm tamper;

BS2_LIFT_ALARM_FLAG alarmFlags;
uint8_t reserved[3];
} BS2Lift;
  1. liftID

    Lift ID

  2. name

    Name of the lift.

  3. deviceID

    ID of the device taht is connected to the lift.

  4. activateTimeout

    Time for the lift to be closed after it has been opened. The unit is seconds.

  5. dualAuthTimeout

    Interval between the first user's authentication and the second user's authentication. The unit is seconds.

  6. numFloors

    Number of floors that is configured to the lift.

  7. numDualAuthApprovalGroups

    Number of access groups having authority of dual authentication.

  8. dualAuthApprovalType

    Decides whether to distinguish if the user belongs to an access group having authority when accessing the door .

    ValueDescription
    0None
    1Check the last user's authority
  9. tamperOn

    The status of the tamper.

  10. dualAuthRequired

    Flag that indicates whether dual authentication is enabled.

  11. dualAuthScheduleID

    Schedule for the dual authentication. Set the value as 0 for disable, 1 for enable, or set a schedule ID.

  12. floor

    Floor information of the lift, which can be configured up to 255 floors.

  13. dualAuthApprovalGroupID

    List of access groups having dual authentication authority, which can be configured up to 16 access groups.

  14. alarm

    Alarm that will be triggered when the sensor input gets detected, which can be configured up to 2 alarms.

  15. tamper

    Alarm that will be triggered when the tamper gets detected on the lift.

  16. alarmFlags

    Status of the door alarm.

  17. reserved

    Reserved space.

BS2LiftFloor​

typedef struct {
BS2_DEVICE_ID deviceID;
uint8_t port;
BS2FloorStatus status;
} BS2LiftFloor;
  1. deviceID

    Device ID.

  2. port

    Relay port number.

  3. status

    Status of the floor.

BS2FloorStatus​

typedef struct {
BS2_BOOL activated;
BS2_FLOOR_FLAG activateFlags;
BS2_FLOOR_FLAG deactivateFlags;
} BS2FloorStatus;
  1. activated

    Determines whether the floor is activated or deactivated.

  2. activateFlags

    The priority of when the floor gets activated, which will not operate if the priority is lower than the deactivate priority. For example, if the floor is activated with the operator priority, all users entry will not be allowed. The deactivateFlags and activateFlags cannot have the same priority besides the default priority NONE.

    ValueDescriptionPriority
    0NoneNormal
    1ScheduledHigh
    4OperatorVery High
    2EmergencyHighest
  3. deactivateFlags

    The priority of when the floor gets deactivated, which will not operate if the priority is lower than the activateFlags priority.

    ValueDescriptionPriority
    0NoneNormal
    1ScheduledHigh
    4OperatorVery High
    2EmergencyHighest

BS2LiftSensor​

typedef struct {
BS2_DEVICE_ID deviceID;
uint8_t port;
BS2_SWITCH_TYPE switchType;
uint16_t duration;
BS2_SCHEDULE_ID scheduleID;
} BS2LiftSensor;
  1. deviceID

    Device ID.

  2. port

    Input port number.

  3. switchType

    Type of the switch.

    ValueDescription
    0Normally open
    1Normally closed
  4. duration

    다The time that will take to determine an input signal as a fire alarm. The unit is milliseconds.

  5. scheduleID

    ID of the time schedule when to operate the lift.

BS2LiftAlarm​

typedef struct {
BS2LiftSensor sensor;
BS2Action action;
} BS2LiftAlarm;
  1. sensor

    Sensor that detects the activate/deactivate status of the lift.

  2. action

    Action that the lift will execute.

BS2LiftStatus​

typedef struct {
BS2_LIFT_ID liftID;
uint16_t numFloors;
BS2_LIFT_ALARM_FLAG alarmFlags;
BS2_BOOL tamperOn;
BS2FloorStatus floors[BS2_MAX_FLOORS_ON_LIFT];
} BS2LiftStatus;
  1. liftID

    Lift ID.

  2. numFloors

    Number of floors that is allocated to the lift.

  3. alarmFlags

    Alarm status of the lift.

    ValueDescription
    0None
    1First alarm
    2Second alarm
    4Tamper
  4. tamperOn

    The status of the tamper.

  5. floors

    Floor information of the lift, which can be configured up to 255 floors.

BS2FloorLevel​

typedef struct {
BS2_FLOOR_LEVEL_ID id; // id >= 32768 (BS2_ACCESS_LEVEL_ID <ㅇ 32768)
char name[BS2_MAX_FLOOR_LEVEL_NAME_LEN];
uint8_t numFloorSchedules;
uint8_t reserved[3];
BS2FloorSchedule floorSchedules[BS2_MAX_FLOOR_LEVEL_ITEMS];
} BS2FloorLevel;
  1. id

    Floor ID. The floor ID should start from 32768. This is due to the level ID used for access levels which is maximum 32767.

  2. name

    Name of the floor.

  3. numFloorSchedules

    Number of time schedules that is allocated to the floor.

    Reserved space.

  4. floorSchedules

    List of time schedules allocated to the floor.

BS2FloorSchedule​

typedef struct {
BS2_LIFT_ID liftID;
uint16_t floorIndex;
uint8_t reserved[2];
BS2_SCHEDULE_ID scheduleID;
} BS2FloorSchedule;

  1. liftID

    Lift ID.

  2. floorIndex

    Floor ID.

  3. reserved

    Reserved Space.

  4. scheduleID

    Time shceulde ID.

Was this page helpful?