Skip to main content

Product Specifications

Provides key specifications of the product, including size, features, and performance.

Credentials

Biometric

Fingerprint

  • Image Dimension:

    272 x 320 pixels

  • Image Bit Depth:

    8 bits, 256 grayscale

  • Resolution:

    500 dpi

  • Template:

    SUPREMA / ISO19794-2 / ANSI-378

  • Extractor / Matcher:

    MINEX certified and compliant

  • Live Fingerprint Detection:

    Supported (HW + SW based)

RF Card
BEW2-OHPB

125kHz EM, HID Prox & 13.56MHz MIFARE, MIFARE Plus, DESFire, DESFire EV1/EV2/EV3, FeliCa

BEW2-ODPB

125kHz EM & 13.56MHz MIFARE, MIFARE Plus, DESFire, DESFire EV1/EV2/EV3, FeliCa

BEW2-OAPB

125kHz EM, HID Prox & 13.56MHz MIFARE, MIFARE Plus, DESFire, DESFire EV1/EV2/EV3, FeliCa, iCLASS SE/SR/Seos

RF Read Range

EM/MIFARE/DESFire/HID iCLASS: 50 mm, HID Prox/FeliCa: 30 mm

Mobile

NFC, BLE

General

CPU

1.2 GHz Quad Core

Memory

2 GB Flash + 256 MB RAM

Crypto Chip
Supported
LED

Multi-color

Sound

Multi-tone Buzzer

Operating Temperature

-20 °C ~ 50 °C

Storage Temperature

-40 °C ~ 70 °C

Operating Humidity

0 % ~ 80 %, non-condensing

Storage Humidity

0 % ~ 90 %, non-condensing

Authentication

CE, UKCA, KC, FCC, IC, RCM, BIS, ANATEL, SIG, RoHS, REACH, WEEE, ETL Listed to UL 294

Capacity

Max. User

500,000

Max. Credentials (1:N)

Fingerprint: 100,000

Max. Credentials (1:1)
  • Fingerprint: 500,000
  • Card: 500,000
Max. Text logs

1,000,000

Interface

Ethernet

Supported (10/100 Mbps, auto MDI/MDI-X)

Network Protocol

TCP, UDP

RS-485

1 ch Master / Slave (Selectable)

RS-485 Communication Protocol

OSDP V2 compliant

Wiegand

1 ch Input / Output (Selectable)

Input

2 ch Inputs

Relay

1 relay

PoE

Supported (Power over Ethernet 44 VDC Max 12 W, IEEE 802.3af)

Tamper
Supported

Electrical

Power
12 Vdc

Current: Max. 0.5 A

Switch Input VIH
  • Min.: 3 V
  • Max.: 5 V
Switch Input VIL

Max.: 1 V

Switch Pull-up Resistance

4.7 kΩ (The input ports are pulled up with 4.7 kΩ.)

Wiegand Output VOH

More than 4.8 V

Wiegand Output VOL

Less than 0.2 V

Wiegand Output Pull-up Resistance

Internally pulled up with 1 kΩ

Relay
  • 2 A @ 30 VDC Resistive load
  • 1 A @ 30 VDC Inductive load

Dimensions and Weight


1) DESFire EV2/EV3 cards are backward compatible with DESFire EV1 cards, supporting CSN and smart card features, including those of the DESFire EV1 card.

2) RF read range will vary depending on installation environment.

3) UL Safety Standard - Access Control Device

  • Destructive attack - Level 2 / Line security - Level 2 / Endurance - Level 1 / Standby power- Level 1

4) Based on users enrolled without credentials.

Info

Product specifications are subject to change without notice for performance improvement.

Was this page helpful?