Firmware Version 1.2.0 (Build No. 1.2.0_251014)
Release|2025-10-21
-
After upgrading the firmware to v1.2.0, it is not able to downgrade to an earlier version of the firmware.
-
For more information, check the serial number of the device and contact the Suprema.
New Features and Improvements
-
Supports the Master Admin setting, which grants full administrator privileges.
-
Reflects global cybersecurity standards and the latest security requirements.
-
Added identification code to support recognition of the latest cards.
- DESFire EV3
-
Improved time synchronization behavior between server and devices.
-
Improved keypad UI when entering username or ID.
Bug Fixes
-
When using Device → Server mode, the server IP address is reset if the connection to the DHCP server fails. Affects version: 1.0.0
-
When a user with more than two cards enrolled attempts card authentication to the Wiegand output device, the ID of a card other than the authenticated card is output. Affects version: 1.0.0
-
Arm/Disarm actions did not operate correctly on specific Supervised Input port of the DM-20 connected as a slave. Affects version: 1.0.0
-
Each time the Device Info menu is opened, the WiFi MAC address is displayed differently. Affects version: 1.1.0
-
Wiegand format card data of 25 bits or less is not recognized. Affects version: 1.0.0
-
When multiple devices are connected to a third-party control panel, rebooting one device causes the RS-485 connections of the other devices to be disconnected. Affects version: 1.1.0
-
After a firmware upgrade, authentication failure occurs with the previously used cards. Affects version: 1.1.0