Firmware Version 1.5.0 (Build No. 1.5.0_210628)
Release|2021-07-08
Main Fixes
- Incorrect temperature was displayed when authenticating from a slave device with the thermal camera. Affects version: 1.4.0, 1.4.1, 1.4.2
New Features and Improvements
-
Occupancy limit zone support
-
Added support for the option to toggle Screen Saver for slave devices.
-
Improved manually turning the secure tamper on or off even when the default hash key is set.
-
Separated event logs of Mobile Access cards and RFID cards.
-
Improved that the thermal camera works first when both the thermal camera and Wiegand bypass are set.
-
Changed to a new touch pad
-
For devices with firmware version 1.4.2 or earlier, please follow the instructions below when replacing the front cover (touch pad).
-
Replace the front cover after upgrading the firmware to version 1.5.0 or later.
-
If you have already replaced the front cover before upgrading the firmware to version 1.5.0 or later, please upgrade to the latest version firmware again.
-
-
Bug Fixes
-
The RS-485 communication did not work properly when connecting the device to a third-party controller after activating the Secure Communication mode. Affects version: 1.4.2 or earlier
-
A large number of 'Door closed' logs occurred abnormally when the door sensor was set to the input port of Secure I/O 2 connected as a slave device.
-
Added defensive code to initialize if an error in the IR LED value occurs. Affects version: 1.3.0 or earlier
-
The screen was abnormally displayed when the second user authentication was successful on a slave device with dual authentication. Affects version: 1.4.2 or earlier
-
An abnormal event log occurred when the temperature measurement failed after setting the temperature mode to 'Temperature Check Before Authentication'. Affects version: 1.4.0, 1.4.1, 1.4.2
-
An abnormal event log occurred when measuring temperature after setting the temperature mode to 'Check Temperature Only'. Affects version: 1.4.0, 1.4.1, 1.4.2
-
The changed settings were reflected in the log but were not displayed properly on the screen when the time and attendance code settings were changed. Affects version: 1.4.2 or earlier
-
The relay operated as Off (Lock) after setting the scheduled unlock zone in the elevator and rebooting the master device. Affects version: 1.4.2 or earlier
-
The performed action, such as temperature output, was different from the intended action responding to the input signal set in the Trigger & Action feature when using the Suprema Thermal Camera. Affects version: 1.4.0, 1.4.1, 1.4.2
-
An issue of Suprema Thermal Camera screen being maintained even when the thermal imaging camera was toggled from 'Enabled' to 'Disabled'. Affects version: 1.4.0, 1.4.1, 1.4.2
-
The device abnormally terminated when establishing a communication connection with 'Device → Server'. Affects version: 1.4.2 or earlier
-
All files in the database were deleted after exporting them to a USB. Affects version: 1.4.2 or earlier
-
The slave device rebooted abnormally. Affects version: 1.4.2 or earlier
-
The RS-485 disconnection log continuously occurred when Secure I/O 2 was connected. Affects version: 1.4.2 or earlier
-
Ten administrators were still not deleted from the device when initializing the device that has 1,000 assigned administrators. Affects version: 1.4.2 or earlier
-
Device registration using Mobile Access app does not work on dynamic sites. Affects version: 1.4.2 or earlier
-
The Wiegand reader operated as Unlock after setting the Wiegand reader connected to DM-20 to Lock and rebooting the device when using the device with DM-20. Affects version: 1.4.2 or earlier
-
When enrolling a new fingerprint to AoC, it was able to authenticate the user with both the new fingerprint data and the existing fingerprint data. Affects version: 1.4.2 or earlier
-