Firmware Version 1.1.0 (Build No. 1.1.0_210813)
Release|2021-08-13
New Features and Improvements
-
Added devices that support fingerprint
- X-Station 2 Finger (XS2-ODPB, XS2-OAPB)
-
Intelligent Slave Support
- Intelligent Slave: A function that enables 1:1 or 1:N matching directly from the Suprema device and transmits the authentication result as OSDP card data to the third-party controller.
-
Improved manually turning the secure tamper on or off even when the hash key is set.
Bug Fixes
-
When setting an elevator as a schedule unlock zone, related logs were not displayed properly. Affects version: 1.0.0
-
The device was rebooted abnormally when selecting all data, exporting them via a USB flash drive, and then importing user data on the device storing maximum user and text log data (500,000 users, 5,000,000 text logs). Affects version: 1.0.0
-
When scanning a card with XPass D2 (XPD2-GDB, XPD2-MDB) connected as a slave, it did not fail immediately and waited for input after setting the Private Mode to Card + PIN. Affects version: 1.0.0
-
The firmware upgrade failed in the device connected as a slave. Affects version: 1.0.0
-
It was not able to enroll fingerprint in some devices that were connected as a slave. Affects version: 1.0.0
-
When the authentication mode was set to Card + Fingerprint in the slave device, the authentication failed. Affects version: 1.0.0
-
The RS-485 communication did not work properly when connecting the device to a third-party controller after activating the Secure Communication mode. Affects version: 1.0.0
-
The firmware upgrade from v1.0.3 or earlier to v1.1.0 failed. Affects version: 1.0.0
- When upgrading the firmware from 1.0.3 or earlier to 1.1.0 or later, upgrade to 1.1.0 firmware first, and then upgrade to the later version firmware again.
-
The connection to the server was lost when accessing the Ethernet menu on the device. Affects version: 1.0.0
-
When accessing the menu through ID authentication on a device with T&A mode set and moving back to the home screen, the T&A caption was not displayed. Affects version: 1.0.0
-
If some ports of the OM-120 connected as a slave are set as a door relay and the device is rebooted, the relay was operated abnormally. Affects version: 1.0.0
-
An abnormal IP address was set when using DHCP. Affects version: 1.0.0
-
When the connection to BioStar 2 was lost, an 'Upgrade Failed' message was displayed regardless of the situation. Affects version: 1.0.0
-
When searching event logs on the device, the date selection popup screen was still displayed after the Menu Timeout. Affects version: 1.0.0