Firmware Version 1.1.4 (Build No. 1.1.4_220805)
Release|2022-08-05
XS2-APB, XS2-QAPB and XS2-OAPB types of X-Station 2 model support HID iClass card type through SE processor.
For devices with the new SE processor, after upgrading the firmware to v1.1.4 or higher, you cannot downgrade to a lower version and downgrade the firmware customized in the lower version.
Devices with existing SE processor can be downgraded to a lower version.
For more information, check the serial number of the device and contact the Suprema.
New Features and Improvements
-
Improved the OSDP ID to also be deleted when a security tamper occurs on the X-Station 2 connected as a slave device.
-
Supports the dual SE processor.
Bug Fixes
-
When the LAN cable connected to the device is disconnected and reconnected, it takes a long time for IP to be assigned by DHCP. Affects version: 1.0.0
-
Intermittent Mobile Card not authenticating. Affects version: 1.0.0
- Improved BLE Micom Firmware and BLE Recovery RFCore.
-
Master device reboots when you modify the number of Floor in a Zone → Scheduled Unlock. Affects version: 1.0.0
-
The modification is not applied when setting the Intelligent Slave-related settings in the detailed information of registered devices in BioStar 2. Affects version: 1.1.2
- Intelligent Slave: A function that enables 1:1 or 1:N matching directly from the Suprema device and transmits the authentication result as OSDP card data to the third-party controller.
-
Recently issued iClass Seos card from HID not recognized by device. Affects version: 1.0.0
-
Device reboots when card is continuously authenticated. Affects version: 1.0.0