Firmware Version 1.2.0 (Build No. 1.2.0_221209)
Release|2022-12-13
XS2-APB, XS2-QAPB and XS2-OAPB types of X-Station 2 model support HID iClass card type through SE processor.
For devices with the new SE processor, after upgrading the firmware to v1.1.4 or higher, you cannot downgrade to a lower version and downgrade the firmware customized in the lower version.
Devices with existing SE processor can be downgraded to a lower version.
For more information, check the serial number of the device and contact the Suprema.
New Features and Improvements
-
Supports activating licenses for use of specific features on devices.
-
Supports QR code recognition and authentication using the camera.
-
Supports setting the byte order for smart cards.
- Supports setting the byte order of data to be output to Wiegand or OSDP.
-
Separated the log related to the cause of the door unlock.
-
Door open request by exit button
-
Door open request by operator
-
-
Added relay deactivation option for exit button input.
- Added the option to set the door open request log to occur but the relay not to operate when the exit button is pressed.
-
Added the Use QR as card option.
- Supports selecting whether to allow authentication when the QR data scanned by the device is the same as the card data issued to the user.
-
Improved to select and update only the desired information when updating user information.
-
Improved the font size of the toast message.
Bug Fixes
-
Global APB behavior for the same input was different depending on firmware version. Affects version: 1.0.0
-
When communicating with a 3rd party control panel via OSDP, the device does not respond to the Device Capabilities command. Affects version: 1.0.0
-
When communicating with a 3rd party control panel via OSDP, the device incorrectly responds as 'Inactive' when receiving the Input Status Request command while the input port is grounded. Affects version: 1.0.0
-
When communicating with a 3rd party control panel via OSDP, the device does not respond to the Output Status Report command while the relay reacts to it. Affects version: 1.0.0
-
When communicating with a 3rd party control panel via OSDP, the device incorrectly responds as 'Inactive' when receiving the Output Status Request command while the relay status is 'On'. Affects version: 1.0.0
-
Deleting all users included in an access group in BioStar 2 does not delete the access group from the device's user information. Affects version: 1.0.0
-
When using the card to authenticate to the device, the card that was normally authenticated fails intermittently. Affects version: 1.0.0
-
Improved the structure to prevent authentication fail caused by broken database or cache memory. Affects version: 1.0.0
-
User name, ID, and message overlap when applying Device Private Msg. using SDK. Affects version: 1.0.0