Skip to main content

Change the Main Server IP Address

Use this document when the server's network environment changes or when you need to change the IP address after initial setup. Learn how to safely change the BioStar X main server IP address and reconfigure the connected Multi Communications Server.

Info

The main server IP address change feature is supported in BioStar X v1.0.2 or later.

Change IP address​

First, change the IP address on the server where BioStar X is installed. Change the IP address of the network adapter connected to the external network.

Info

For more information about changing the IP address on Windows, see Microsoft Customer Support.

Apply the new IP address​

Follow the steps below to change the IP address on the server where BioStar X is installed.

BioStar X IP Setting​

Use the BioStar X IP Setting tool to change the IP address.

  1. In Windows, click Start → BioStar X → BioStar X IP Setting.

  2. When the BioStar X IP Setting window appears, select the IP address in Server Address.

  3. Click Apply.

  4. If a message about the IP address change appears, review it and click Yes.

  5. Wait until the IP address change process completes. When the process completes, a success message appears.

  6. If the IP change applied successfully message appears, click OK.

After the IP address change completes, all services restart.

Info
  • The IP address cannot be entered manually; select one from the IP addresses listed in Server Address.

  • The new IP address appears in BioStar X Service Manager → SERVICE SETTINGS → BioStar X Server (Main) under Server Address.

    BioStar X Service Manager Server Address

  • If a device is registered to BioStar X with the Device ▶ Server Connection option, the administrator must manually update that device's server IP address to the new IP address.

Modify database server settings​

If the database is hosted on the same server as BioStar X, stop all services, then edit BioStar X's system.conf file. Skip this step if you are using an external database server.

  1. Stop all services related to BioStar X in Windows Services (service.msc).

  2. Navigate to C:\Program Files\BioStar X Server.

  3. Open the system.conf file with a text editor such as Notepad.

  4. In the database section, change the server_ip value to the new IP address.

  5. Save and close the system.conf file.

  6. Restart all services related to BioStar X in Windows Services (service.msc).

Open a web browser and verify that the server is accessible using the new IP address.

Update Multi Communications Server​

If you installed an additional Multi Communications Server, update its settings to use the main server's new IP address. Follow this procedure on the server where you installed the Multi Communications Server.

  1. Navigate to C:\Program Files\BioStar X Communications Server.

  2. Run biostar-device-cert-enroll.exe.

  3. When the Certificate Enrollment window appears, enter the new main server IP address in the Main Server IP Address field.

  4. If the main server port number differs from the default (21810), enter the new port number in the BioStar X Coordinator Service Port field.

  5. Click Enroll.

When the main server IP address update completes, a success message appears.

Info
  • If you did not install a Multi Communications Server, skip this step.

  • If you changed the port number on the main server where BioStar X is installed, run BioStar X Service Manager on the main server and check the Client Port value under SERVICE SETTINGS → BioStar X Coordinator Service.

  • For more information about installing the Multi Communications Server, see Install the Multi Communications Server.

Was this page helpful?