Custom Installation
This guides the user on how to set up a Custom installation to integrate with a database that the user has already installed.
-
The databases that can be used in integration with BioStar X are as follows.
-
MariaDB 10.1.10
-
MS SQL Server 2012 SP3
-
MS SQL Server 2014 SP2
-
MS SQL Server 2016 SP1
-
MS SQL Server 2017
-
MS SQL Server 2019
-
MS SQL Server 2022
-
-
MS SQL Server communication security supports TLS 1.2.
-
If the database table creation fails when MS SQL Server is set as the Database Type, you can create the table by executing the script in C:\Program Files\BioStar X\dbscript\mssql folder.
-
When installing with Custom installation, AC DB name, TA DB name, and VE DB name cannot be set the same.
-
To use Windows authentication, Microsoft ODBC Driver 17 for SQL Server is required. Please install the driver first.
Installation Guide
-
Go to the Suprema Download Center, log in, and download the installation package (BioStar X Setup.X.Y.Z.BB.exe).
-
Run the downloaded installation file.
-
Select the language to use and select the OK button.
-
To continue the installation, select I accept the agreement and click the Next button.
-
Enter the administrator account password and click the Next button.
-
Select Custom installation and click the Next button.
-
Enter the details of the pre-configured database and click the Next button.
-
Set the installation path for BioStar X and click the Next button.
-
Set the path to store the encryption key and click the Next button.
-
Read the information about the management and responsibility of personal information stored in the database, and click the Next button to continue the installation.
-
Set the port for BioStar X communication and click the Next button.
-
Select the components of BioStar X and click the Next button. If you select USB Device Agent, the USB Agent and driver for using BioMini, BioMini Plus 2, BioMini Slim 2, and DUALi DE-620 will be installed together.
-
When all preparations for installation are complete, click the Install button.
-
Select whether to install additional programs and click the Finish button.
-
Complete the installation of USB Device Agent by following the instructions on the installation screen.
-
In the downloaded file name,
X.Y.Z
is the version information andBB
is the build number. -
The administrator account password is used when logging in for the first time after installing BioStar X.
-
The root account password for the database is used as the initial password for AC, TA, and Video DB.
-
The storage path for the encryption key can be changed. If you modify or move the encryption key file after changing the path, a system error may occur.
-
When BioStar X is deleted, the encryption key file is also deleted.
-
The provided USB Device Agent certificate can only be applied to the local network.
-
If another program is using port 443, the BioStar X Setting program runs automatically and allows you to change the port number. For details on changing the port number, refer to the following.
-
For more information about changing database settings, refer to the following.
-
Be careful not to lose the administrator or root account password for the database.
-
If you lose the password, version upgrade and DB backup/restore may not be possible.