Fire Alarm Zone
This guide describes how to set fire alarm zones. A fire alarm zone is a designated area where all doors or elevators are set to open or lock when a fire occurs.
Register fire alarm zone
-
Click Settings on the Launcher page.
-
Click Advanced AC on the left sidebar.
-
Click ADD ADVANCED AC.
-
Select Fire Alarm and click Apply.
-
Enter the name of the fire alarm zone to be added in the Info section.
-
Set the details of the fire alarm zone in the Settings section. For more information, refer to the following.
-
Set the actions to be performed when a fire alarm occurs in the Alarm section.
-
After completing all settings, click Apply at the bottom of the screen.
Setting options guide
You can modify fire alarm zone settings.
-
Set the scope of the zone with Mode.
-
Local: You can set the zone only with the entry device and devices connected via RS-485.
-
Global: You can set the zone with all devices registered to BioStar X.
-
-
Enable or temporarily deactivate zone settings with Enabled / Disable.
-
Select the doors to designate as the fire alarm zone with Door.
-
Select the elevators to designate as the fire alarm zone with Elevator.
-
Click + Add and set the devices to trigger fire alarm signals with Device / Input.
-
Setting the Mode option to Local allows you to designate only one door or elevator as a fire alarm zone.
-
Setting the Mode option to Global allows you to designate both doors and elevators as fire alarm zones simultaneously.
-
For more information about device registration, refer to the following.