Ir al contenido principal

Version 1.0.3 (Build No. 1.0.3.171)

Release|2026-09-22

New Features and Improvements​


  1. Supported new device
    • XPass Q2: XPQ2-DPB
    • XPass 2 (V2): XP2-GDPB-V2, XP2-GKDPB-V2, XP2-MAPB-V2, XP2-MDPB-V2, XP2-MAPB-H-V2
  1. Added real-time status monitoring and direct control of doors and elevators in the Monitoring preview
  1. Added face authentication features
    • Added support for Multi Face Authentication (device license required)
    • Added support for tailgating prevention (Anti-Tailgating)
    • Added support for Duplicate Authentication Prevention
  1. Added Include On-Site Users Only mode to Roll Call
  1. Added Scan ID feature to automatically fill in user information using an ID
  1. Added Export/Import Device Configuration feature
  1. Supported EV2 Secure Messaging authentication for DESFire EV2 and EV3 cards.
  1. Added the ability to select and batch control multiple devices in Monitoring
    • Run Unlock Device, Release Lockout, Stop Action, Reconnect, and Reboot on multiple devices at once
  1. Added support for Select All and group selection in the Monitoring event filter
  1. Added the ability to select and batch control multiple doors, elevators, and advanced access control in Monitoring
  1. Added a feature to manage users with long-term inactivity
    • View users with long-term inactivity based on Last Access
    • Set a policy to automatically deactivate users based on conditions
    • Send a pre-notification email to designated recipients before auto deactivation
  1. Separated firmware builds for CE and Global (Non-CE) products.

    CE and Global (Non-CE) products can be identified via the label sticker on the back of the product. The Master Admin feature is enabled only on products with a label bearing the CE mark.

  1. Added Auth Fail Lockout feature, which locks the device after repeated PIN authentication failures.
  1. Expanded allowed characters for User ID and User Name
    • Added support for periods (.) in User ID
    • Added support for periods (.) and apostrophes (') in User Name
  1. Added the Audit Trail feature to T&A
  1. Added a filter to the Monitoring status tree that shows only items requiring attention
  1. Added the ability to configure account permissions at the submenu level
  1. Added the Idle Screen Video Playback feature
    • Supported models: BioStation 3 Max
  1. Supported an option to select QR authentication using the device camera upon Camera QR license activation on XS2-QDPB and XS2-QAPB models.
  1. Added the ability to display frequently used Quick Actions directly in the header
  1. Added the Door Control through Authentication feature, which unlocks or normalizes a door through user authentication
  1. Added the ability to display and unlock locked devices in the Monitoring status tree
  1. Improved license policy and added bulk activation
    • Feature add-on licenses can now be activated on the Essential tier
    • Separated Advanced Access Control into individual licenses
    • Added the ability to activate multiple license keys at once
  1. Added the report save feature to All Events and Alert History in the Data menu
  1. Improved the Access Control Audit Trail feature
    • Expanded logging to capture previously missing actions
    • Recorded before-and-after values when settings or information change
    • Added logging of user information access
  1. Improved the Device menu tree to remember the expanded/collapsed state per account
  1. Added element-specific icons and improved the expand/collapse method in the Monitoring status tree
  1. Improved Monitoring to display the event log across the full screen when there are no maps or cameras to show
  1. Improved the Settings menu with a group tree structure
  1. Improved the VMS certificate installation process
  1. Improved the T&A screen UI design
  1. Improved the Monitoring map status tree to move to the corresponding map when double-clicking a facility
  1. Improved the device hardware version to display the same value as the product label (requires supported firmware)
  1. Changed Secure Communication with Device to be enabled by default
  1. Improved group mapping for users belonging to multiple groups in Entra ID.
  1. Improved Send Face Mobile Enrollment Link to indicate in the Audit Trail that the change was made via this feature.
  1. Improved the display timing and behavior of the notification popup for an existing BioStar X folder when upgrading from BioStar 2 to BioStar X.
  1. Improved the behavior where unnecessary error popups appeared due to response delays during Sync Device.
  1. Improved the group selection UI when creating custom levels.
  1. Security vulnerability improvements
    • Upgraded internal server and client communication channels to TLS 1.3
    • Updated AngularJS and jQuery versions
    • Improved Reverse Tabnabbing vulnerability
    • Enhanced session cookie security
    • Updated the Log4j library version
    • Updated Java Runtime Environment (JRE) version
    • Improved SQL Injection vulnerability
    • Improved a redirect URL security vulnerability during Entra ID login
    • Updated the commons-text library version
    • Updated the OpenSSL library version
    • Updated security vulnerability-related libraries
    • Improved security vulnerabilities in Entra ID integrated login authentication.
  1. Improved login to transmit passwords in encrypted form.
  1. Enhanced security by requiring the current password when changing your own password.
  1. Time & Attendance security vulnerability improvements
    • Improved an SSL certificate-related security vulnerability
    • Updated Node.js and library versions
  1. Improved Face user synchronization performance.
  1. Improved Custom Report query performance when retrieving data over a wide date range.
  1. Performance and query improvements in large-scale environments
    • Improved face authentication performance in environments with many users and face data
    • Improved bulk edit speed for 1,000 or more users
    • Fixed query failures when Device, Access Level, or Credential numbers are large
  1. Improved event query performance for custom accounts using specific device groups.
  1. Improved Door Status query performance in Multi Communication Server environments.
  1. Improved the query performance of the Status tab in the Access Group screen in large-scale environments.
  1. Improved the long synchronization time when saving Door settings.
  1. Improved slow server startup in environments with many registered licenses.
  1. Improved slow user retrieval in environments with many Access Groups.
  1. Improved slow loading of the Elevator detail screen in environments with many devices.
  1. Improved synchronization in Multi Communication Server environments
    • Improved so that each server processes only its own devices for firmware synchronization
    • Improved User Group query performance in environments with many users
  1. Improved delays in saving settings when the Dashboard has many components.
  1. Improved operator permission check performance and Zone permission handling
    • Improved operator permission check performance in environments with many targets
    • Improved Zone permissions being applied incorrectly in some cases
  1. Improved device list tree loading speed in environments with many devices.
  1. Improved device synchronization speed in environments with many devices.
  1. Improved device synchronization by sending updates only for modified users when Access Group members are changed.
  1. Improved overall device synchronization performance and resolved device disconnection issues by sending only device-relevant information during sync.
  1. Added removal of unused files during upgrade.

Bug Fixes​


  1. During video playback, the seekbar timeline and the time information at the knob position do not match. Versión afectada: 1.0.0
  1. Viewing the preview of a disconnected Slave device does not display the device group. Versión afectada: 1.0.0
  1. Exporting to CSV after selecting all users exports them in user creation order instead of User ID order. Versión afectada: 1.0.0
  1. Switching views or exiting full screen while a video is paused causes the video to switch to playing. Versión afectada: 1.0.0
  1. When sorting (Order By) columns in the User List in an encrypted environment with User IDs that differ only by case, the sort order is applied incorrectly. Versión afectada: 1.0.0
  1. When printing the User List after selecting all columns including Custom User Fields, Credential-related columns appear blank. Versión afectada: 1.0.0
  1. Viewing the preview of real-time event logs containing user information that does not exist on the server displays an empty User field. Versión afectada: 1.0.0
  1. When importing a CSV file with Mobile Access Card information, the card is issued only in the Airfob Portal even if user creation fails. Versión afectada: 1.0.0
  1. When importing a CSV file with Mobile Access Card information, a card is issued in the Airfob Portal and an error occurs if User ID is not selected on the column mapping screen. Versión afectada: 1.0.0
  1. Importing a CSV file without Mobile Access Card information deletes the card from BioStar 2 while retaining it in the Airfob Portal. Versión afectada: 1.0.0
  1. The enlarge image button label in the Monitoring event preview area was displayed in English even when the language was set to Korean. Versión afectada: 1.0.0
  1. Unrelated settings were disabled or an info icon was incorrectly displayed when setting Suprema Smart Card Layout or Custom Smart Card Layout to None in Device Detail page. Versión afectada: 1.0.0
  1. Loading not completing when an administrator without device permissions accesses the Occupancy Limit zone Preview in Monitoring. Versión afectada: 1.0.0
  1. Column not printed when a Custom User Field is added and included in the Column Layout before printing. Versión afectada: 1.0.0
  1. Options in CSV Import hidden and unable to proceed when the browser zoom level is increased. Versión afectada: 1.0.0
  1. Error popup occurring when reissuing a Mobile Access Card after deleting it on the user detail page. Versión afectada: 1.0.0
  1. Incorrect screen displayed after completing registration in environments with many users in T&A. Versión afectada: 1.0.0
  1. Error popup occurring intermittently when accessing the device detail page. Versión afectada: 1.0.0
  1. Synchronization errors occurring on multiple devices when deleting a device after deleting a door in a Multi Communication Server environment. Versión afectada: 1.0.0
  1. Checkboxes not working correctly when selecting/deselecting master sub-devices in Set Filters of the Dashboard. Versión afectada: 1.0.2
  1. Image files saved without detailed information in the filename when downloading images in Custom Report. Versión afectada: 1.0.2
  1. Lines misaligned when a User Group name is long in the tree of the Users Information screen. Versión afectada: 1.0.2
  1. Dump files generated after PC boot in an MSSQL environment. Versión afectada: 1.0.0
  1. No action or error message occurring when viewing the Image Log of a disconnected device in All Events. Versión afectada: 1.0.2
  1. Errors occurring when importing a device's Event Log that exceeds the maximum storage capacity. Versión afectada: 1.0.0
  1. Inactive users incorrectly shown as active when searching users via the API. Versión afectada: 1.0.0
  1. Logs from certain devices not appearing in the Event Log and Real-time Log in an MSSQL environment. Versión afectada: 1.0.0
  1. App crashing when fingerprint scanning fails with BioMini Slim2 in USB Agent. Versión afectada: 1.0.0
  1. Wiegand Card IDs not displayed correctly when generating card-related reports in Report. Versión afectada: 1.0.0
  1. Time Zone fixed to UTC+9 instead of the local server time on the first installation of BioStar X. Versión afectada: 1.0.0
  1. Titles not displayed on some screens when using a monitor in portrait mode. Versión afectada: 1.0.0
  1. Null displayed in the name field when a user without a name is selected as a search condition and the screen is refreshed in T&A Report. Versión afectada: 1.0.0
  1. Errors occurring when accessing the Settings menu after upgrading BioStar 2 installed in a Korean-named folder path to BioStar X. Versión afectada: 1.0.0
  1. Errors occurring and the service shutting down when applying settings to certain devices. Versión afectada: 1.0.1
  1. Schedules failing to be created and the loading state persisting in T&A. Versión afectada: 1.0.0
  1. Backup failing when using a custom port in an MSSQL (Windows Authentication) environment. Versión afectada: 1.0.0
  1. Plugin icons not appearing in the Launcher after backup and restore. Versión afectada: 1.0.0
  1. Some files remaining undeleted after uninstalling the T&A package. Versión afectada: 1.0.0
  1. Users not synchronizing correctly to Time & Attendance when adding a large number of users and User Groups via CSV Import in a Windows Authentication environment. Versión afectada: 1.0.0
  1. Duplicate leave entries created when registering Leave for multiple users in T&A. Versión afectada: 1.0.0
  1. Time adjustment buttons not being disabled when adding a non-worked leave in a T&A Schedule. Versión afectada: 1.0.0
  1. Errors occurring when disabling Optimized Punchlog in T&A in MSSQL environments. Versión afectada: 1.0.0
  1. Unnecessary characters displayed in the popup message when creating a schedule in T&A. Versión afectada: 1.0.0
  1. Error logged when creating a holiday in T&A menu with the same name as a holiday created in Schedule setting menu. Versión afectada: 1.0.0
  1. Some attendance records missing when using multiple devices in T&A in an MSSQL environment. Versión afectada: 1.0.0
  1. Holidays not applied to schedules and processed as absences when there are more than 100 holidays in T&A. Versión afectada: 1.0.0
  1. Memory usage increasing abnormally when using T&A for extended periods. Versión afectada: 1.0.0
  1. Warning popup appearing when the refresh button is clicked repeatedly in the Time & Attendance calendar view. Versión afectada: 1.0.0
  1. Some communication servers failing to connect after a reboot. Versión afectada: 1.0.0
  1. Mobile cards incorrectly added to the Deleted CSN Mobile Card list when deleting them via CSV import in a Dynamic site environment. Versión afectada: 1.0.0
  1. Browser freezing when importing a large number of user groups from Active Directory/Entra ID. Versión afectada: 1.0.0
  1. Some event names not displayed correctly after upgrade. Versión afectada: 1.0.0
  1. Incorrect data displayed in Custom Report when changing rows per page after navigating pages. Versión afectada: 1.0.2
  1. Intermittent errors occurring during restore in an MSSQL (Windows Authentication) environment. Versión afectada: 1.0.2
  1. Active Directory/Entra ID integration failing in language environments with different numeral representations, such as Arabic. Versión afectada: 1.0.0
  1. Users who have exited still shown as inside in the Muster Report. Versión afectada: 1.0.0
  1. Time and Attendance synchronization not proceeding after an error occurs during synchronization. Versión afectada: 1.0.0
  1. Remote Access failing to start or save properly. Versión afectada: 1.0.2
  1. Old IP information remained and caused improper operation when restoring with a changed server IP Versión afectada: 1.0.2
  1. Synchronization failing when an Entra ID group name contains special characters such as commas (,) or equal signs (=). Versión afectada: 1.0.0
  1. Errors occurring due to invalid dates when modifying access groups via the API. Versión afectada: 1.0.0
  1. User ID not displayed in Face synchronization failure events. Versión afectada: 1.0.0
  1. The same firmware appeared twice when upgrading firmware with both XPass 2 (V2) and XPass 2 Keypad (V2) selected in the Device list Versión afectada: 1.0.0
  1. The Apply button did not work when saving RS485 settings on the device detail screen Versión afectada: 1.0.0
  1. The server did not restart automatically after an abnormal shutdown Versión afectada: 1.0.0
  1. Features supported by the new firmware were not displayed on the screen after a firmware upgrade Versión afectada: 1.0.1
  1. The report title was not displayed when printing or exporting to PDF if the Roll Call report title was in Thai Versión afectada: 1.0.0
  1. The server shut down abnormally and interrupted service for all users when a logged-in user was deleted Versión afectada: 1.0.0
  1. The event was not displayed in the event log when controlling a door in Monitoring without ever opening the preview Versión afectada: 1.0.0
  1. No system backup file was created in Time & Attendance environments upgraded from BioStar 2 Versión afectada: 1.0.0
  1. Deleting all Output Signals in the Alert settings failed to process Versión afectada: 1.0.0
  1. Anti-Passback list retrieval was delayed when entering the Advanced Access Control screen after creating a Muster zone, making the menu inaccessible Versión afectada: 1.0.0
  1. Bookmarks and notifications were not recorded in the VMS when the web port was set to a non-default port during installation Versión afectada: 1.0.0
  1. After a user group operation failed once, subsequent user changes were not applied to devices until the server was restarted Versión afectada: 1.0.0
  1. Images could not be added when setting the BioStation 3 Max home screen logo to a slide show Versión afectada: 1.0.2
  1. Users belonging to both Access Group disappeared from devices after reconnection when the Access Level of the two groups were swapped while the devices were disconnected Versión afectada: 1.0.0
  1. Events from a deleted device remained and delayed event logging for other devices, and the server log grew rapidly if the deleted device stayed connected Versión afectada: 1.0.2
  1. Real-time event, alarm, and task completion notifications were not displayed on the screen when their delivery failed Versión afectada: 1.0.0
  1. IP information was not displayed in the User column when viewing login failure lockout events in Custom Report Versión afectada: 1.0.0
  1. The scroll bar in the User tree and the Settings screen could not be moved with the mouse Versión afectada: 1.0.0
  1. Some users were not delivered to devices during full device synchronization, yet the synchronization was marked as complete, and they were still not delivered even after resynchronizing Versión afectada: 1.0.0
  1. Changing the personal data encryption settings logged the user out Versión afectada: 1.0.0
  1. The authenticated user name was not displayed in the Occupancy Limit alert Versión afectada: 1.0.0
  1. On the Custom Report screen, the User Name column also displayed the user ID, duplicating the User ID column Versión afectada: 1.0.0
  1. User synchronization on BioStation 3 Max was slow in specific device synchronization mode environments Versión afectada: 1.0.2
  1. Re-entering the Door Status tab after applying a manual Lock/Unlock (Timed, Permanent) to a door relay does not display the status change tooltip when clicking the Door Relay icon. Versión afectada: 1.0.0
  1. Re-entering the Door Status tab after applying a manual Lock/Unlock (Permanent) to a floor relay does not display the status change tooltip when clicking the Floor Relay icon. Versión afectada: 1.0.0
¿Fue útil esta página?